Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

 GYxtw  Optical cable  Physical PropertiesFiber CountNominal Weight(kg/km)Nominal Weight(lb/kft)Nominal Outer Diameter(mm)Nominal Outer Diameter(in)Maximum Pulling LoadInstallation(N/Ib)In Service(N/Ib)2-24389.0261.0712.6*25.10.50*0.992670/600890/20036-72429.0287.9214.7*27.10.58*1.072670/600890/20096-144571.0

Featured Products

 GYxtw  Optical cable 
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

 Physical Properties
Fiber CountNominal Weight(kg/km)Nominal Weight(lb/kft)Nominal Outer Diameter(mm)Nominal Outer Diameter(in)Maximum Pulling Load
Installation(N/Ib)In Service(N/Ib)
2-24389.0261.0712.6*25.10.50*0.992670/600890/200
36-72429.0287.9214.7*27.10.58*1.072670/600890/200
96-144571.0383.2220.2*32.60.80*1.292670/600890/200
2-24303.0203.369.1*21.50.36*0.852670/600890/200
36-72332.0222.8211.1*23.50.44*0.932670/600890/200
96-144417.0279.8715.9*28.30.63*1.122670/600890/200

   Physical Properties
Fiber CountNominal Weight(kg/km)Nominal Weight(lb/kft)Nominal Outer Diameter(mm)Nominal Outer Diameter(in)Maximum Pulling Load
Installation(N/Ib)In Service(N/Ib)
2-24389.0261.0712.6*25.10.50*0.992670/600890/200
36-72429.0287.9214.7*27.10.58*1.072670/600890/200
96-144571.0383.2220.2*32.60.80*1.292670/600890/200
   Mechanical Properties
Minimum Bending Radius: Maximum Compressive Load:4000N for unarmored cables;
Under installation:20×OD 6000N for armoured cables
During operation0×OD for unarmoured cablesRepeated Impact:4.4 N.m (J)
 20×OD for armoured cablesTwist (Torsion):180×10 times, 125×OD
Temperature Range: Cyclic Flexing:25 cycles for armoured cables.
Operating Temperature Range:-40ºC(-40ºF) to +70ºC(+158ºF) 100 cycles for unarmoured cables.
Storage Temperature Range:-50ºC(-58ºF) to +70ºC(+158ºF)Crush Resistance:220N/cm (125lb/in)
   Fiber Compliance
Temperature Cycling 
Tensile Strength 
Crush 
Impact 
Repeated Bending 
Torsion 
Kink 
Cable Bend 
Cool Bend
IEC60794-1-2-F2 
IEC60794-1-2-E1A
IEC60794-1-2-E3 
IEC60794-1-2-E4 
IEC60794-1-2-E6 
IEC60794-1-2-E7 
IEC60794-1-2-E10 
IEC60794-1-2-E11 
IEC60794-1-2-E11
   Safety Compliance
General Purpose GradeFlammability Test: OFN (UL1581)
Riser GradeFlammability Test: OFNR/FT4 (UL1666)
Plenum GradeFlammability Test: OFNP/FT6 (UL 910)
FRPVC GradeFlammability Test: IEC60332-1
LSZH GradeHalogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2
LSFROH Grade Halogen Content Test: IEC 60754-1 
Acidity Test: IEC 60754; 
Smoke Emission Test: IEC61034-1/2 
Flammability Test: IEC60332-1 & IEC 60332-3C/A
FR GradeFire Resistance Test : IEC 60331 / BS 6387 CW
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable
Outdoor Central Tube Fiber Optic Cable GYXTW Single Mode Optical Cable 2-12 Core Fiber Cable

 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours