CPRI LC Outddoor cable Assemblies SpecificationApplicationMulti-purpose Outdoor.For connection between distribution box and RRH. 3.Deployment in Remote Radio Head cell tower applications. Features1.Easily add/install jumper cables for a future expansion.2.Low insertion loss and added loss.3.Height of attenuation.4

Featured Products

CPRI LC Outddoor cable Assemblies Specification

Application

  1. Multi-purpose Outdoor.
  2. For connection between distribution box and RRH.
  3. 3.Deployment in Remote Radio Head cell tower applications.
 

Features

1.Easily add/install jumper cables for a future expansion.
2.Low insertion loss and added loss.

3.Height of attenuation.
4.Flexibility with small bending radius and excellent cable routing properties.
5.End-face geometry and quality superior than IEC and Telcordia standards.
6.The material in the jumpel cable are all-weather and
 UV-resistant.

7.Mechanical performance: IEC 61754-20 standard.
8.RoHS and REACH materials compliant.

Connector Types

 
TypeReferenceNote


LC


IEC 61754-20

Single mode duplex
APC: Green connectors , Green boots UPC: Blue connectors , White boots
Multimode duplexUPC: Grey Connectors , White boots
Dimensional Diagrams

1. CPRI LC Outddoor cable Assemblies
Waterproof Outdoor Cpri LC Outdoor Cable Fiber Optic Patch Cable

 

Patch cord versions

Jumper tolerance requirement
Overall length (L) (M)length of tolerance(CM)
0<L≤20+10/-0
20<L≤40+15/-0
L>40+0.5%L/-0

Cable Structure
Waterproof Outdoor Cpri LC Outdoor Cable Fiber Optic Patch CableCable Parameters

 


Cable Count

Out sheath Diameter
(MM)


Weight
(KG)
Minimum allowable Tensile Strength (N)minimum allowable Crush Load
(N/100mm)
Minimum Bending Radius (MM)
Storage temperature
(ºC)
short termlong termshort termlong termshort termlong term
25.0±0.2308004002000100020D10D-20 ~~ +70

Waterproof Outdoor Cpri LC Outdoor Cable Fiber Optic Patch CableCable Parameters
 


Cable Count


Out sheath Diameter
(MM)


Weight
(KG)
Minimum allowable Tensile Strength (N)minimum allowable Crush Load
(N/100mm)
Minimum Bending Radius (MM)

Storage temperature
(ºC)

short term

long term

short term

long term

short term

long term
25.0±0.2454008002000300020D10D-20~~+70


Cable Structure
Waterproof Outdoor Cpri LC Outdoor Cable Fiber Optic Patch CableCable Parameters

 



Cable Count


Out sheath Diameter
(MM)



Weight
(KG)

Minimum allowable Tensile Strength (N)

Minimum allowable Crush Load
(N/100mm)

Minimum Bending Radius (MM)


Storage temperature
(ºC)

short term

long term

short term

long term

short term

long term
27.0±0.3mm5060010001000200020D10D-20~~+70
Cable Structure

Waterproof Outdoor Cpri LC Outdoor Cable Fiber Optic Patch CableCable Parameters

 


Cable Count


Out sheath Diameter
(MM)


Weight
(KG)
Minimum allowable Tensile Strength (N)minimum allowable Crush Load
(N/100mm)
Minimum Bending Radius (MM)

Storage temperature
(ºC)
short termlong termshort termlong termshort termlong term
27.0±0.36860010002000300020D10D-20~~+70

Optical Characteristics
 

Item
Parameter
Reference
Single modeMultimode
Insertion lossTypical value≤0.15dB;Maximum≤0.30Typical value≤0.15dB;Maximum≤0.30IEC 61300-3-34

Return loss
60dB (APC);
50dB (UPC)

30dB (UPC)

IEC 61300-3-6

End-Face Geometry
 
ItemUPC (Ref: IEC 61755-3-1)APC (Ref: IEC 61755-3-2)
Radius of curvature (mm)7 to 255 to 12
Fiber height (nm)-100 to 100-100 to 100
Apex offset (μm)0 to 500 to 50
APC angle (°)/8° ±0.2°
Key error (°)/0.2° max

End-Face Qualty (SM)
ZoneRange (μm)ScratchesDefectsReference
A: Core0 to 25NoneNone


IEC 61300-3-35:2015
B: Cladding25 to 115NoneNone
C: Adhesive115 to 135NoneNone
D: Contact135 to 250NoneNone
E: Rest of ferruleNoneNone


End-Face Qualty (MM)
 
ZoneRange (μm)ScratchesDefectsReference
A: Core0 to 65NoneNone


IEC 61300-3-35:2015
B: Cladding65 to 115NoneNone
C: Adhesive115 to 135NoneNone
D: Contact135 to 250NoneNone
E: Rest of ferruleNoneNone

Mechanical Characteristics
 
TestConditionsReference
Endurance500 matingsIEC 61300-2-2
VibrationFrequency: 10 to 55Hz, Amplitude: 0.75mmIEC 61300-2-1
Cable retention400N (main cable); 50N (ranch part)IEC 61300-2-4
Strength of coupling mechanism80N for 2 to 3mm cableIEC 61300-2-6
Cable torsion15N for 2 to 3mm cableIEC 61300-2-5
Fall10 drops, 1m drop heightIEC 61300-2-12
Static lateral load1N for 1h (main cable); 0.2N for 5min (ranch part)IEC 61300-2-42
Cold-25°C, 96h durationIEC 61300-2-17
Dry heat+70°C, 96h durationIEC 61300-2-18
Change of temperature-25°C to +70°C, 12 cyclesIEC 61300-2-22
Humidity+40°C at 93%, 96h durationIEC 61300-2-19




 